Aseptic Inline Filling System

Biomedical Contract Manufacturing Facility   Irvine, California

Assignment:  Optimize motion control hardware and software to improve synchronization of fill needle and capping mechanisms with product conveyor.

 

Solutions:  Implemented hardware upgrades to allow on-the-fly resync based on offset data from integrated vision system. Developed new Galil DMC application to replace existing software that failed to meet performance objectives.

339 10th Street, Seal Beach CA 90740    ā€¢  714.981.5694